2.3. DOSAGE OPERATION
It is important to remember that the buttons and control units receive signals in the two main switch supply positions on the machine.
In the first position, the switch will only operate the automatic water filling, but not the heating elements.
In the second position, the switch receives a signal from the starter relay (optional) and this allows the machine to be heated and dispense coffee. It is recommended that this be done when the machine is hot and the working pressure in the boiler(s) has been reached, as indicated by the green range on the gauge (11), and/or shown on the display, if the machine has one.
2.3.1. Programming dose on the control unit
Section titled “2.3.1. Programming dose on the control unit”In order to program the dose you must press the 'non-stop' button on the left button pad (group 1) for 5 seconds, and the non-stop coffee LED will come on (*).






At this point programming can be started for the four coffee selections. When the desired quantity of coffee is obtained, press the selection once again and the dosing will stop. The same operation will have to be followed for all buttons.
By carrying out this process all the groups will be programmed automatically.






The selections that are already programmed will appear with their LEDs off. When this happens it is still possible to modify the dose in the same manner as indicated above.






If the LED for the selection set is flashing during the programming of the dose, it means that the volume counter is not sending a signal to the control unit, and at the end of the dosing the dose will be zero. Programming without water. It is recommended that the flow meters be checked.
Non-touchscreen display.
Touchscreen display.
Manual doses programming activated. |
2.3.2. Programming the electronic pre-brew
Section titled “2.3.2. Programming the electronic pre-brew”The control unit has a function called ‘pre-brew’. Pre-brew can be enabled or disabled. If your machine has a visual display, it will be possible to carry out this action via an option on the display. If it does not have a display, the function is performed in the following manner:

To enable pre-brew, switch off the machine’s main switch and press the button 1 espresso on the left button pad (group 1), keep it pressed and set the main switch to position 1 or 2, either will do, and the 1 espresso LED will light up.
Release the button and set the switch to zero (OFF) and then set it in the working position (position 2).






To disable pre-brew, set the machine’s main switch to zero (OFF) and press the button 1 coffee, keep it pressed and set the main switch to position 1 or 2, either will do, and the 1 coffee LED will light up.
Release the button and set the switch to zero (OFF) and then to position 2.






2.3.3. Activating or deactivating pre-infusion for a long coffees using IB7 and Intenz
Section titled “2.3.3. Activating or deactivating pre-infusion for a long coffees using IB7 and Intenz”The pre-infusion function for the buttons for 1 espresso or 2 espressos can be activated or deactivated. Thus, when the pre-infusion function is enabled, you can decide whether or not to use the pre-infusion function with these buttons.
To activate and deactivate the pre-infusion function, switch off the machine's main switch and simultaneously press and hold the buttons for 1 espresso and 1 long coffee on the left button panel (group 1) and move the machine's main switch to position 1 or 2 (it makes no difference which position you choose). The LED lights of both buttons will light up.
2.3.4. Activating boiler refill while in operation
Section titled “2.3.4. Activating boiler refill while in operation”To maintain a constant pressure while dispensing coffee, Iberital coffee machines are set, by default, to refill the boiler with water once the groups have finished serving coffee. The water is only able to be refilled when there are NO groups in operation.
In establishments with high peak workloads, there could be long periods of time when a group is in operation. So, as a result of the demand for steam or hot water for infusions, a situation could occur in which the boiler water level goes down so much that when the water is able to be refilled, the maximum time specified for refilling is exceeded. Which, for normal machine operation, is less than the time specified for the machine when it starts up.
Once the refill time has been exceeded without having covered the maximum level probe, the machine will display the message “FillingUp time exceeded” and it will cut off.
If this situation occurs with your machine, it is recommended that the “FillingUp+coffee” function be activated so that the water will always be refilled whenever it is below the level probe, even if the groups are in use.
2.3.4.1. Procedure
Section titled “2.3.4.1. Procedure”2.3.4.1.1. Activating the refill function using the Keypad
Section titled “2.3.4.1.1. Activating the refill function using the Keypad”Turn off the machine using the main switch.
Press and hold the button for 2 short coffees from group no.1 (left) and turn on the machine using the main switch.
* Only for IB Connect models.
Once the machine is on, keep the button pressed down for several seconds.
If it has been done correctly, the pressed button will stay lit.
* Sólo para modelos con módulo IB Connect.
Also, on machines that have a display, the following message will appear on the display.
The machine will have to be turned off and on again for the changes to be applied.
2.3.4.1.2. Deactivating the refill function using the Keypad
Section titled “2.3.4.1.2. Deactivating the refill function using the Keypad”Turn off the machine using the main switch.
Press and hold the button for 2 long coffees from group no.1 (left) and turn on the machine using the main switch.
* Only for models with module IB Connect.
Once the machine is on, keep the button pressed down for several seconds.
If it has been done correctly, the pressed button will stay lit.
* Only for models with module IB Connect.
Also, on machines that have a display, the following message will appear on the display.
The machine will have to be turned off and on again for the changes to be applied.
2.3.4.1.3. Activating/deactivating the refill function using the non-touch display (New Iberital)
Section titled “2.3.4.1.3. Activating/deactivating the refill function using the non-touch display (New Iberital)”



To “Enable” or “Disable” the FillingUp+Coffee option, use the UP
or DOWN
buttons.


2.3.5. Programming hot water (only available on Iberital Expression Pro model and optional in New Iberital)
Section titled “2.3.5. Programming hot water (only available on Iberital Expression Pro model and optional in New Iberital)”Enter programming mode, pressing the "non-stop" button for 5 seconds on the button pad for any group; the "nonstop" LED will light up.
- If the option ‘NO’ MIXED TEA is selected on the visual display or for machines without visual display:
- Press the hot water button. At that moment hot water will begin to come from the boiler.
- When the desired dose has been obtained, press the hot water button again.
- The hot water setting has been programmed.
- If the option MIXED TEA is selected on the visual display or for machines without visual display:
- Press the hot water button. At that moment mixed water (hot/cold) will begin to come from the boiler.
- Press the hot water button. At that moment hot water will begin to come from the boiler.
- When the desired dose has been obtained (first press + second press), press the hot water button again.
- The final hot water setting has been programmed.
2.3.6. Automatic steam programming (optional, only available on some models)
Section titled “2.3.6. Automatic steam programming (optional, only available on some models)”When our model has automatic steam (which will always be located on the left), on going through the technical menu we will see the option to change various temperatures:
- LCD display screen (non-touchscreen): on going through the technical menu, we will see the option to change two temperatures:
- Temperature 1: This is the final temperature of the milk, whether hot milk or frothy milk.
- Temperature 2: This is the temperature from which air begins to be injected together with the steam, in order to improve the froth of the milk.
- TFT display screen (touchscreen): In the technical menu we can modify the setting of automatic steam by going to the option "Frother temperature", which can be found in the technical menu, under the first option "Display config." (see section 2.9.3.2.2 of this manual).
- Hot milk: This is the final temperature of the hot milk.
- Frothy milk: This is the final temperature of the frothy milk.
- Air with steam: This is the temperature from which air begins to be injected together with the steam, in order to improve the froth of the milk.
- Compensation for the real temperature of the milk: This is the variation in temperature between the centre of the volume of milk in the jug, and the real temperature acquired by all the milk. This is due to the fact that the temperature sensor is positioned in the centre, exactly where the steam is released.