3.6. BOILER

  1. Feed group.
  2. Injector.
  3. Heat exchanger.

This boiler is manufactured in copper and a heat exchanger connected to the power supply unit passes through it.

During a supply cycle, cold water is pumped to the coffee boiler through the injector. In turn, the water inside the coffee boiler is taken to the feed group. Under rest conditions there is permanent flow of water between the feed group and the coffee boiler, which keeps the equipment at the optimum temperature for coffee preparation.

The temperature of the heating elements within the boilers is limited by thermostats. Should the element temperature exceed that established by the thermostat, the machine will cut the power supply. In order to connect the elements once more, push the reset button located on the thermostat.

MACHINENº of BoilersGroupsResistance
IBERITAL IB711

1800 W 220-240 V

1800 W 110 V

2

3000-3500 W 220-240 V

2400 W 110 V

35000-6000 W 220-240 V
IBERITAL INTENZ11

1800 W 110-220 V

2400 W 110 V

2

3000-3500-3800-5000 W 220-240 V

2400 W 110 V

35000-6000 W 220-240 V
NEW IBERITAL123000-3500-3800-5000 W 220-240 V
35000-6000 W 220-240 V
IBERITAL REFERENT123000 W 220-240 V
35000 W 220-240 V
IBERITAL TANDEM123000-3500-3800-5000 W 220-240 V
35000-6000 W 220-240 V
IBERITAL EXPRESSION PRO223000 W + 1000 W 220-240 V
33000 W + 1000 W 220-240 V
IBERITAL VISTA223000 W + 1000 W 220-240 V
33000 W + 1000 W 220-240 V

In the case of irregular operation in the control of heating elements, the safety valves guarantee the integrity of the boiler, releasing excess pressure and keeping it from going over 0.18 MPa.

The safety valves are manufactured under strict quality control standards and following very demanding technical criteria. Once checked by the manufacturer, they are immediately sealed.

3.6.3. Pressure relief valve (anti-vacuum valve)

Section titled “3.6.3. Pressure relief valve (anti-vacuum valve)”

This valve, located on the boiler, prevents the depressurization of the boiler interior, keeping liquids from being sucked in through the steam ejectors.

  1. Solenoid valve.

The machine has a level sensor (a stainless steel strip that is in contact with the water inside the boiler). The sensor is connected to a control processing unit (CPU) which permanently indicates the water level. When the level is low, the CPU activates the pump and the solenoid valve, allowing water to be fed in until the sensor indicates that it has reached the optimum level.

  1. Level (visualization of max. and min. levels for the boiler water).

The water level can be checked at any time via the water level viewer.

  1. Expansion valve (crucible for opening to 1.2 MPa ±0.1).