No hot water is coming out. What should be checked?

If no hot water is coming out, the first thing to check is whether the machine has boiler pressure and temperature. If there is also no steam or the pressure is low, the problem is usually related to the general heating system.

If the machine is heating correctly and steam is available, then the hot water tap or dispensing system should be checked, along with any possible limescale blockages and, if the machine is equipped with a mixing system, the mixing circuit or mixing valve.

If the rest of the machine is operating correctly, the problem is normally located within the hot water circuit.

Hot water comes out lukewarm. What could be happening?

Symptom: hot water with low temperature, “lukewarm”.

Cause: boiler at low temperature/pressure or hot water outlet mixed/temperature-limited (depending on machine configuration).

Observations: check boiler pressure and temperature and whether the machine recovers properly after usage. If the boiler is within normal values but water is lukewarm, check the mixing valve (if present) or hot water service configuration.

Hot water tap drips or does not shut off. What should be checked?

Symptom: dripping from the outlet or not fully closing.

Cause: worn valve seat or closing element, or limescale buildup; internal seal worn out.

Observations: first purge/operate several times (may remove debris); if it persists, disassemble and replace seals or valve core. Also check for particles in the seat due to insufficient filtration.

Steam wand drips when closed. What usually fails?

Symptom: continuous dripping from the tip with the valve closed.

Cause: worn or dirty valve seat/closing element (limescale), damaged internal seal.

Observations: if dripping worsens over time or with hard water, disassemble the valve, clean the seat and replace the seal kit or closing element. Do not overtighten, as it can deform the seat and worsen the issue.

No steam (only water or nothing comes out). What are the typical causes?

Symptom: when opening steam, nothing comes out or only water, without the typical “hissing”.

Cause: boiler without pressure (not heating) or steam circuit blocked (tip/wand/valve). If nothing comes out, the valve may be blocked or internally closed.

Observations: check the boiler pressure gauge: if it reads zero or low, it is a heating/control issue. If there is pressure but no steam, clean the tip and wand and check the valve (seat/closing element) and possible limescale blockages. Also verify that the vacuum breaker valve works correctly, as failure to release air during filling and heating can create a false pressure reading.

Steam comes out with too much water (wet steam). What causes this?

Symptom: water spurts out before steam; “watery” milk foam.

Cause: boiler overfilled or low temperature/pressure; also insufficient purging of condensate in the steam wand.

Observations: purge for 2–3 seconds before use; if it persists, check the filling system (level probe/auto-fill) and boiler pressure/temperature settings. With hard water, limescale buildup may affect readings or control.

Steam has low power. What should be checked first?

Symptom: weak steam, slow milk texturing, pressure drops quickly.

Cause: low boiler pressure/temperature or partially clogged steam tip.

Observations: check boiler pressure gauge and recovery time; purge the wand and clean/unblock the tip (holes). If pressure does not reach normal values, check heating/control system (pressurestat or probe) and boiler level.