Temperature, heating and pressure
15 questions
Where should the cup warmer power supply cable be connected?
The cup warmer power supply cable must be connected to the upper part of the main power switch.
The connection must be made as follows:
Neutral: connect to terminal 1/L1 or 3/L2, using the contact that has only one wire connected.
Phase: connect to terminal 5/L3 or 7/L4, using the contact that has only one wire connected.
This intervention must be carried out by qualified technical personnel, following the electrical connection criteria defined by Iberital.
The machine switches on but turns itself off after a few minutes. What are the typical causes?
Check whether the machine is entering an alarm condition (keypad and/or display).
Verify whether there is a lockout caused by low water level or a filling timeout alarm, according to the alarm table.
If the machine is equipped with an LCD display, check the message shown to identify the exact cause.
Can a cup warmer be installed on a machine that was not originally equipped with one?
Yes, provided that the machine model supports the installation of a cup warmer.
In this case, the mechanical procedure is the same as for a replacement: the upper tray assembly with the cup warmer must be installed using the corresponding kit.
In addition, it will be necessary to order the cup warmer power supply cable, which is common to all compatible models.
How is an existing cup warmer replaced?
When the machine is already equipped with a cup warmer and it needs to be replaced, the usual procedure is to replace the complete upper tray assembly with the corresponding cup warmer kit.
Cup warmer heating elements are adhesive-mounted and must be installed using specific tools to ensure correct positioning. These tools differ depending on the machine model.
For this reason, individual replacement of the heating element may only be carried out by an official Iberital Service Centre, as it is the only party that has the specific tools required for each model. In these cases, all adhesive residue from the heating element being replaced must be completely removed.
Do all Iberital models have a cup warmer?
No. Not all Iberital models are equipped with a cup warmer as standard.
For models that do include a cup warmer, or that allow one to be installed, it should be noted that each machine model and size uses, or may require, a specific cup warmer heating element part number. (New Iberital / Expression Pro – Iberital Vista – Iberital Tandem).
How long does it take for steam to be available?
There is no single fixed time to state that “the boiler takes X seconds to produce steam”, because this depends on the model, the boiler size, the heating element power, the boiler temperature when the machine is switched on, and whether the boiler is already full or still needs to be filled.
Before steam becomes available, the machine must fill the boiler, heat the water, expel the air inside the boiler and reach its operating pressure.
If it takes longer than usual, it is advisable first to check that the boiler has filled correctly and that the machine is heating normally.
No water is coming out of any group. What should be checked?
If no water is coming out of any group, the issue is usually machine-wide rather than related to a specific group. The first step is to check whether the machine is in an alarm or lockout condition, whether it is filling correctly, whether the pump is operating, and whether water is reaching the machine with sufficient flow rate.
If the fault affects all groups simultaneously, the diagnosis should focus on the water supply, boiler filling, pump and hydraulic circuit.
Another possible cause may be that the flowmeter on group 1 is not sending pulses during dose programming. In that case, while programming, the machine does not receive pulses and the dose may be stored with a value of 0. If programming is carried out button by button, all buttons may end up programmed with a value of 0. Since the left-hand group is the master group, all doses are replicated to the remaining groups and, as a result, no doses are executed (no water comes out of any group).
In these cases:
- Verify that the flowmeter on group 1 is sending pulses (if there are no pulses, the programming may be stored with a value of 0).
- Once pulses have been restored on GR1, reprogram the doses correctly.
Finally, although less likely, complete blockage of all group solenoid valves should not be ruled out, for example after a prolonged machine shutdown. In this case, the internal circuit of each solenoid valve should be inspected.
The espresso machine thermostat trips
If the machine thermostat trips, it means that the boiler has reached an excessive temperature and the safety system has cut off power to the heating element. After this occurs, the machine stops heating until the thermostat is manually reset.
The most common cause is not the thermostat itself, but a fault in the temperature regulation system: pressure switch, temperature probe or SSR, depending on the type of machine.
If the thermostat trips again, the entire thermal control system must be checked before continuing to use the machine.
Coffee is hot but hot water/infusions are not. What should be checked?
In machines with mixing systems (cold and hot water blending), check the hot water solenoid valve; it may not be opening due to blockage, lack of electrical supply, or incorrect dosing configuration.
In dual boiler machines, check the electrical supply to the steam boiler heating element. A fault in temperature regulation may trip the safety thermostat of this boiler, preventing heating; if voltage is present at the element, inspect it as it may be open circuit internally and not producing heat.
One group is hot, but the other is not / or different temperatures. What should be checked?
When a group is used infrequently, it is prone to accumulating deposits in the thermal tube or in the group chamber where the injector (trumpet) is located. This can reduce the water flow section during thermosyphon circulation, resulting in lower temperature in that group compared to more frequently used groups, and therefore lower extraction temperature.
Temperature instability in coffee (some shots are correct and others are cold). What should be checked?
An undersized machine may cause thermal drop during high-demand periods (peak usage), as the heat demand exceeds the machine’s capacity.
Higher power means greater capacity to generate energy.
Larger boiler volume means greater capacity to store energy.
In mono-boiler machines, coffee and hot water/steam circuits share the same thermal system; in dual-boiler or multiboiler machines, these circuits are separated.
Verify that the machine is at operating temperature and that there are no temperature control alarms.
Pump pressure does not reach target (does not exceed X bar). What should be checked?
Pressure in the coffee circuit during extraction is typically 8–9 bar due to pump regulation. If this pressure is not reached:
- Check pump adjustment and whether it responds to regulation.
- Check for losses through the expansion valve due to incorrect adjustment.
Boiler pressure does not increase or increases only slightly. What could be the cause?
Identify whether temperature control is managed by pressurestat, ON/OFF or PID (depending on configuration/control unit).
Check for temperature probe interruption alarms (if the machine uses a probe) or any other alarm such as “Filling time exceeded” that may stop the machine.
Verify if voltage reaches the heating element.
Check if voltage is present at the primary and/or secondary side of the SSR.
Verify that the contactor is engaged (machines with contactor).
Check for excessive limescale buildup on the heating element and boiler.
Measure the machine’s electrical consumption and verify it matches the expected power rating; if lower, it may indicate a partial open circuit in the heating element, reducing performance.
Relation with alarms (if applicable): Alarm table may include “T.ProbeUnconnect” for temperature probe issues.
More information in the manual:
Overheating (overpressure / boiling water). What usually fails?
First confirm the type of control (pressurestat vs probe). A pressurestat configuration on a machine designed for temperature probe control may result in loss of proper temperature regulation.
If probe-controlled:
- Check for incorrect readings (if it triggers an alarm, it will appear in the alarm table).
- With the machine powered off, check continuity in the AC circuit at the SSR. This is normally an open circuit and should not show continuity; if it does, replace the SSR.
- Any condition causing excessive temperature/pressure will lead to safety valve opening and eventually trigger the safety thermostat (heating element protection), resulting in temperature drop and machine cooling. The thermostat must be reset to resume heating.
If pressurestat-controlled:
- If the pressure gauge indicates high pressure (above the green range), reduce and adjust the cut-off pressure. Open the steam valve to lower temperature and observe pressure recovery.
Check that the circuit opens correctly when exceeding the set pressure.
More information in the manual:
Machine does not heat or takes a very long time to heat up. What should be checked?
Identify whether temperature control is managed by pressurestat, ON/OFF or PID (depending on configuration/control unit).
Check for temperature probe interruption alarms (if applicable), or any other alarm such as “Filling time exceeded” that may stop the machine.
If temperature is pressure-controlled (pressurestat):
- Check whether the vacuum valve opens correctly. If air cannot be expelled during filling and heating, it may create a false pressure reading due to air compression rather than steam generation.
- Check pressurestat adjustment. If the gauge indicates low pressure (below the green range), the setting may be too low. Increase the cut-off pressure using the pressurestat adjustment screw.
Check whether voltage reaches the heating element.
Check whether voltage is present at the primary and/or secondary side of the SSR.
Verify that the contactor is engaged (machines with contactor).
Check for excessive limescale buildup in the heating element and boiler.
Measure electrical consumption and verify it matches the expected power rating; if lower, it may indicate a partial open circuit in the heating element.
Relation with alarms (if applicable): Alarm table may include “T.ProbeUnconnect”.
More information in the manual: