Filling, boiler and water level
8 questions
How long does it take for the boiler to fill up completely?
There is no single fixed time to state that “the boiler takes X seconds to fill completely”, because this depends on the model, the boiler size, the heating element power, the water pressure and the inlet water flow rate.
What is clearly defined is the following:
- If, during machine operation, the water level probe is not covered again within the allowed time, a filling timeout alarm will be triggered.
- The machine does not use the same filling time in all situations
- During start-up, a longer filling time is allowed because the machine does not yet know whether the boiler is completely empty or still contains part of the water level.
- During normal operation, this time is shorter because the machine already knows that the level probe has previously been covered and only needs to recover the missing water.
Note: This shorter time also acts as a safety measure. If there were a connection failure between the level probe and the control unit, the machine could continue filling without stopping. By limiting the filling time, boiler overflow, safety valve activation and water leakage that could result in flooding are prevented.
Suggestions: In the event of a filling issue, a recommended first action is to switch the machine off and then back on again, as in certain situations this may help the machine complete the initial filling process correctly.
- This may be particularly necessary during commissioning, especially if the machine operates with a bottle or tank system without mains water pressure. Under normal conditions, the coffee circuit can fill automatically through mains pressure even when the machine is switched off, but this behaviour does not occur when there is no inlet pressure.
- If this situation occurs repeatedly during normal operation, one initial option is to allow water filling during extraction, enabling the machine to recover the water level even while groups are dispensing coffee. This situation is most common during periods of high demand and particularly on machines with small boilers.
- It may also be necessary when the inlet water flow rate is low, since the larger the boiler, the more likely it is that the available filling time will be insufficient to complete the filling process correctly.
- In addition, this situation may worsen over time if the hydraulic circuit contains limescale build-up, dirt or partial blockages, as any restriction further reduces the actual filling capacity.
If, after several attempts, the machine still fails to fill, it should no longer be considered a temporary start-up condition and the appropriate corrective actions will need to be taken.
More information in the manual:
How to perform a boiler drain step by step (holiday mode)
Boiler draining is carried out with the machine switched off and is used to leave the boiler completely empty before an extended shutdown period or before certain maintenance procedures.
Steps
- Switch the machine OFF using the main power switch.
- Open the steam taps or steam valves.
- Wait until no more steam is released.
- Close the steam taps or steam valves.
- Open the manual boiler drain valve.
- Keep the valve open until the boiler is completely empty.
- Close the drain valve.
If you want to put the machine back into service
- Switch the machine on.
- Allow it to complete the boiler filling process.
- Do not return the machine to normal operation until the filling process has been completed correctly.
Points to consider
· The drain valve may be located directly on the boiler or on the drain tray, depending on the model.
· This procedure refers to draining the boiler, not the water tank of a Handy machine.
How to disable water filling during dispensing?
To disable water filling during dispensing, always do so with the machine switched off. Switch it on while holding down the corresponding keypad button combination and continue holding it for a few seconds after start-up. If the deactivation is successful, the buttons will remain illuminated. Then switch the machine off and on again to apply the change.
- On Iberital IB7 and Iberital INTENZ models without display, without temperature probe and without IoT, it is disabled on group 2 by pressing buttons 2 + 3 + 5 simultaneously (2 Short Coffees + 1 Large Coffee + Continuous).
- On Iberital VISTA, EXPRESSION PRO, NEW IBERITAL, Iberital TANDEM, Iberital REFERENT, and also on Iberital IB7 / Iberital INTENZ models with display, temperature probe or IoT, it is disabled on group 1 using button 4 (2 Large Coffees).
If the machine is equipped with a display, the following message will appear:
"Filling + Coffee DISABLED"
Additionally, on machines with a display, this function can be disabled through the technical menu using the "Filling + Coffee" option.
Water filling during dispensing, how to enable it
By default, Iberital machines are configured to fill the boiler only when no coffee extraction is taking place, in order to maintain pressure stability during dispensing.
This function allows the machine to fill the boiler with water even while a group is dispensing coffee. It is used during periods of high demand, when the machine may not have sufficient time to recover the water level between services.
To enable water filling during dispensing, the machine must be switched off. Switch it on while holding down the corresponding keypad button combination and continue holding it for a few seconds after start-up. If the activation is successful, the buttons will remain illuminated. Then switch the machine off and on again to apply the change.
- On Iberital IB7 and Iberital Intenz models without display, without temperature probe and without IoT, it is activated on group 2 by pressing buttons 1 + 3 + 5 simultaneously. (1 Short Coffee + 2 Short Coffees + Continuous).
- On Iberital Vista, Expression Pro, New Iberital, Iberital Tandem, Iberital Referent, and also on Iberital IB7 / Iberital Intenz models with display, temperature probe or IoT, it is activated on group 1 using button 3 (1 Large Coffee).
On models with a display, the following message will appear: "Filling + Coffee ENABLED"
Additionally, on machines with a display, this function can be enabled through the technical menu using the "Filling + Coffee" option.
Machine continuously filling with water (does not stop). What could be the cause?
If there is an alarm indication:
- Check whether the maximum level probe is detecting correctly (dirt, limescale) or if it is disconnected.
- If the machine has a display, adjust the probe sensitivity. Very soft water with low mineral content has lower conductivity and may prevent proper level detection.
- Check the exact indication on the control panel/display and compare it with the alarm table (in tank machines, this may indicate an empty tank requiring manual refill).
- Check the earthing connection. Poor grounding can cause incorrect operation of level probes.
- Also check conductivity between the boiler and earth.
If there is no alarm indication but filling is continuous, it is likely due to a fault in the fill solenoid valve (not closing properly) or incorrect installation direction of the valve.
More information in the manual:
Water drains during filling. Is this normal?
A constant drip from the expansion valve is normal, as it regulates internal pressure. If water is discharged in large amounts abnormally or during pump operation:
- Check the pump pressure; it should be between 8 and 9 bar. Adjust if higher.
- Adjust the expansion valve to 11–12 bar. A portafilter with pressure gauge must be used for this adjustment.
Machine stops and repeatedly triggers a filling alarm during operation. What should be checked?
If after restarting the machine (power cycle) it fills correctly and the alarm disappears, the issue may be due to two causes:
“Allow filling while coffee is being dispensed” configuration
By default, Iberital machines are configured to fill the boiler only when no group is dispensing, in order to maintain stable pressure during extraction.
During peak usage (when at least one group is always active), the level may drop and, when filling is finally allowed, the maximum time may be exceeded, triggering a “Filling time exceeded” alarm with lockout.
This configuration can be modified:
Enable
IB7/INTENZ without display/probe/IoT: GR2 buttons 1+3+5 simultaneously.
VISTA / EXPRESSION PRO / TANDEM / REFERENT / (IB7/INTENZ with display/probe/IoT): GR1 button 3.
Display: “FillingUp+Coffe ENABLED”.
Disable
IB7/INTENZ without display/probe/IoT: GR2 buttons 2+3+5 simultaneously.
VISTA / EXPRESSION PRO / NEW IBERITAL / TANDEM / REFERENT / (IB7/INTENZ with display/probe/IoT): GR1 button 4.
Display: “FillingUp+Coffe DISABLED”.
Insufficient flow or restriction: Low inlet flow or restriction (limescale or similar) may increase filling time beyond normal limits and exceed the allowed time. Increase flow if possible. If no obstruction is found or flow cannot be increased, filling times may be adjusted.
There are two different filling times:
Initial filling time (fixed, not adjustable).
Normal operation filling time (safety function to prevent boiler overfilling if probe fails). Default 15 seconds, adjustable.
When should filling time be adjusted?
Only if the machine repeatedly triggers filling timeout alarms after verifying flow and obstructions.
Time selection combinations:
Short (15 s): GR1 → 1 + 4
Medium (30 s): GR1 → 2 + 4
Long (60 s): GR1 → 3 + 4
Steps (general method with machine OFF)
Switch off the machine.
Press and hold the required combination.
Switch on the machine while holding the buttons until confirmation (LEDs on or display message), then release.
- To apply changes, switch OFF and ON again.
Warning: Modifying this value reduces safety protection in case of level probe failure, which may result in boiler overfilling and safety valve discharge.
Machine does not fill with water (boiler not filling). What should be checked?
Identify whether there is a level/filling alarm (control panel or display) (e.g.: temperature probe interrupted, empty boiler, filling time exceeded).
Relation with alarms (if applicable): Check alarms related to level/filling: “Empty boiler”, “Probe interrupted”, “Boiler filling / Time-out alarm”.
If the machine has a tank, it may be an indication that the tank is empty and needs to be manually refilled.
Verify water supply (mains or tank depending on version) and machine shut-off valve.
- Check whether electrical voltage reaches the pump motor:
- Check voltage at the female connector supplying the motor.
- Check voltage between neutral and the control unit output to the pump motor (see diagram on control unit cover). If no voltage is present, the issue lies in the control unit relay.
- Check whether electrical voltage reaches the fill solenoid valve or if it actuates (test magnetism with a screwdriver at the bottom of the coil).
- Voltage present and magnetic: Hydraulic issue (stuck core, closed manual valve or obstruction at boiler inlet).
- Voltage present but no magnetism: Coil filament discontinuity. Replace coil.
- No voltage:
- Check electrical wiring at the solenoid connector and continuity of phase and neutral with the control unit terminal (see diagram).
- Check voltage between neutral and control unit output. If no voltage is present, the issue lies in the control unit relay.
Check the exact indication on the control panel/display and compare it with the alarm table.
More information in the manual: