10 questions

Where can I find the manual for my machine?

Locate the rating plate (model).

Check the documentation provided with the machine or request it from the installer/distributor.

On the Iberital website, in the IBDocs section (https://docs.iberital.com/), you can find all the documentation for your machine.

More information in the manual:

Besides group cleaning, what else can I do as a user to maintain the machine?

Symptom: reduce breakdowns and maintain cup quality.

Cause: most issues come from dirt, milk residues in the steam wand, and clogged drains/filters.

Observations:

  • Steam: purge before/after use and clean the wand (damp cloth + purge).
  • Portafilters/baskets: daily cleaning; weekly degreasing.
  • Drip tray and drain: empty and clean daily; ensure proper drainage.
  • Group/showers: perform regular group cleanings.
  • Water: monitor the filter (dates/liters) and check for leaks.
  • Habits: do not leave coffee in the portafilter or dirty groups at closing.

Before calling technical service, what checks can I perform?

Symptom: machine stopped, alarms or malfunction.

Cause: many issues are related to supply (water/electricity), configuration or basic cleanliness.

Observations:

  • Confirm power supply (breaker/RCD, plug, switch).
  • Confirm water supply (valve open, filter not closed, mains pressure, tank full if applicable).
  • Check display messages or keypad LEDs (note the pattern).
  • Try purging hot water and steam (if boiler is operational).
  • Perform group flush and clean the shower if flow is irregular.
  • Check the drain (not blocked or overflowing).
  • If the breaker trips or there is a burning smell: stop and call service.

How often should the water softener filter be replaced?

A water softener loses capacity (resin/carbon) depending on water consumption and hardness, so it cannot be defined only by time.

Replacement is based on liters or time (whichever comes first): typically every 6 months to 1 year, but the correct approach is to follow the cartridge capacity/counter and measure hardness/TDS.

Once installed, it is important not to exceed 1 year of use, even if the filter still has remaining capacity.

In filters with activated carbon, after one year the material may begin to degrade and release residues into the machine.

Different water types require different filters or softeners (hard water, sulfate water, etc.).

A water analysis is recommended to select the appropriate filter and adjust it to the machine’s consumption.

For more information, follow the manufacturer’s recommendations.

What should I do if the machine has not been used for several days?

Symptom: first startup after inactivity, risk of off-flavors, blockages or leaks.

Cause: stagnant water, accumulated oils, possible air in the circuit, dried seals.

Observations:

  • Purge hot water and steam (partially refresh the boiler water).
  • Perform group flush (with and without detergent if needed).
  • Clean showers and portafilters.
  • Discard the first test shots.
  • If there is strong odor or very dirty water, perform a deeper cleaning and check water treatment.

When should the group gasket and shower screen be replaced?

Symptom: leaks from the portafilter, difficult locking, uneven puck imprint, deformed shower screens or uneven water flow.

Cause: mechanical wear + temperature + dirt (the gasket hardens; the shower screen deforms or becomes clogged).

Observations: typical guideline:

  • Gasket: replace when leaking, when the portafilter “locks too far to the end”, or every 4–6 months depending on usage.
  • Shower screen: replace if deformed or clogged, if it does not recover after cleaning, or typically every 4–6 months depending on usage.
    (In high-volume locations, it may be sooner.)

What symptoms does a machine that is “dirty” inside (groups and valves) show?

Symptom: persistent rancid or bitter taste, shower screens with residues, coffee splashing, irregular flow rates, group dripping, unusual leaks/returns, stiff lever handles or “lazy” solenoid valves.

Cause: coffee oils + grounds + limescale (depending on water) in the shower screen, diffuser and valves (3-way valve, group valve).

Observations: if it improves after flush and shower cleaning, it was dirt buildup. If it returns quickly, review cleaning habits and water quality.

How often should group cleaning be performed?

Symptom: preventive maintenance / rancid flavors / dark shower screens.

Cause: buildup of coffee oils and particles in the group and valves.

Observations: typical technical service practice:

  • Flush with water several times a day.
  • Backflushing with blind filter:
    • Without detergent:
      • Daily, at the end of the day, in medium/low-volume use.
      • Several times a day in high-volume use.
    • With detergent:
      • Weekly in high-volume use.
      • Fortnightly or monthly in medium/low-volume use.

(Adjust according to usage volume and the detergent/manufacturer recommendations.)

What type of detergent should be used for group cleaning?

Use a specific detergent such as an espresso machine cleaner, in powder or tablet form, alkaline and non-abrasive (food-safe).

Avoid:

  • Dishwashing detergents, generic degreasers or “multi-purpose” products (they may damage seals, chrome parts and leave odors).
  • Descaling agents for group cleaning (they are intended for boilers or specific circuits, not for routine group cleaning).

Can my machine perform automatic cleaning?

Most Iberital machines include an automatic cleaning function that can be activated individually per group using a button combination:

IB7 and Intenz: press buttons 5 (continuous) and 1 (single short coffee) simultaneously

Automatic cycle:

  • 15 s extraction
  • 2 s pause
  • 7 repetitions

New Iberital, Tandem, Referent, Expression Pro and Vista: press buttons 5 (continuous) and 2 (single long coffee) simultaneously

Automatic cycle:

  • 7 s extraction
  • 3 s pause
  • 4 repetitions

Important notes

  • Automatic cleaning:
    • Requires a blind portafilter.
    • Can be done with or without detergent, depending on the cleaning type.
  • If the combination does not start a cycle, the control board may not include this feature.
  • The automatic cleaning cycle cannot be configured, it is predefined by the control board.