Power on, power supply and “dead machine”

12 questions

Connection of power button wiring – Iberital Tandem / Referent / Expression Pro / Vista

The switch operates as a normally open contact which, when latched, closes the circuit and supplies voltage to its outputs.

All terminals on the switch cap are male terminals.

  • There are two input wires connected to the switch:
    • Red wire: this is the phase wire and is connected to the brown wire with a female terminal coming from the contactor.
    • Orange wire: this is the neutral wire and is connected to the orange wire with a female terminal coming from the contactor.

When the switch is pressed, phase and neutral are passed to the outputs and supply power to the remaining wires, which are the switch output wires.

To make the connection correctly, simply connect the male Faston terminals of the switch to the female terminals of the machine wiring harness as follows:

  • Black wires: these are two phase supply wires and can be connected interchangeably, one by one, to the black wires with female terminals on the machine wiring harness.
  • Blue wires: these are three phase supply wires. One is a single wire and the other is a wire that bridges a second line on the same Faston terminal.
    • The individual switch wire is connected to one of the blue wires of the machine wiring harness, which has a bridge in the connector.
    • The bridged wire with two blue terminals is connected interchangeably to either of the two remaining blue wires with female terminals on the machine wiring harness.

Connection of power button wiring – Iberital Tandem / Referent / Expression Pro / Vista

How far to refill a machine with a water tank (portable machine)

Portable machines with a water tank are equipped with a maximum water level indication system that operates as detailed below:

When manually refilling the water tank and the maximum level is reached, the LED of the continuous button remains illuminated while all the other LEDs remain off, indicating that water should no longer be added to the tank. This LED will remain illuminated until the water level drops below the maximum level probe, at which point all buttons will remain illuminated.

Note: all buttons remain fully functional during the maximum filling alarm, even if they are not illuminated.

When to refill a machine with a water tank (portable machines)

Portable machines with a water tank are equipped with a minimum water level indication system that operates as detailed below:

When the water tank reaches its minimum level, the control unit cuts off the power supply to the keypad and the heating element to prevent damage to both the heating element and the pump due to a lack of water. At that moment, the keypad LEDs begin to flash, indicating to the user that the tank must be refilled.

When the tank is manually refilled and the water covers the minimum level probe, the LEDs switch off and the control unit restores power to the heating element and the pump.

The machine sometimes switches itself off and on

If a machine switches off and then switches back on by itself, or if the control unit resets, it may be due to different causes related to the electrical installation or to a machine component:

· Problems with the earth connection.

A faulty earth connection may cause interference or unstable operation of the electronic components.

· Problems with the electrical supply.

A sudden voltage drop, brief power interruptions, electrical noise or a poor-quality power supply may cause the control unit to restart. This can occur, for example, when other equipment is connected to the same electrical line, especially appliances with motors or compressors, such as refrigerators, bottle coolers, cold rooms or other similar equipment.

In any of the situations described above, it is recommended that the installation be inspected by a qualified electrician.

· Faulty solenoid valve coil.

A deteriorated solenoid valve coil may draw more current than normal. This can cause a voltage drop in the electronic board and lead to a control unit restart.

Check the condition of the solenoid valve coils. If the problem persists, it is recommended that the installation be inspected by a qualified electrician, also verifying the condition of the earth connection.

The machine becomes locked and we have to switch it off and on again to continue working

A machine lock-up may be caused by various factors such as alarms, activation of OFF mode, or accessing a special configuration during the machine's initial start-up.

The alarms that may cause this situation are:

  • Filling alarm (this is the most likely in machines with small boilers or very high peak workloads). If this occurs continuously, choose to modify the operating mode and allow water filling during dispensing.

Search in the FAQs for Water filling during dispensing, how to perform it

  • Temperature probe alarm exceeded or short-circuited (if the machine is equipped with one)

Check whether there has been any issue with the SSR temperature control components, as this is a probe-controlled machine, and reset the thermostat if necessary. With the machine switched off, check continuity between the input and output of all SSR circuits and replace any SSR that shows continuity between its poles.

Another possible cause is that the temperature probe has short-circuited, causing a high reading to be detected by the control unit. In this case, the temperature probe should be replaced.

  • Temperature probe disconnected alarm:

If the machine is equipped with one, it may be making poor contact. Check the wiring at the extension cable and at the control unit connection terminal itself.

If the machine is not equipped with one, the issue is caused by an incorrect machine configuration. It is configured as ON/OFF when it should be configured as thermostat. To solve the issue, change the configuration through the technical menu or perform a machine reset so that the regulation mode can be auto-configured.

Other situations:

  • When switching the machine on using the main power switch, the machine enters a special configuration function due to a button combination being pressed during start-up, before loading the normal operating firmware.
  • The machine has entered OFF mode (machines with displays, IoT-connected machines, and some versions without a display such as Tandem). Since the machine is switched off by firmware, it remains inactive until its status is changed back to ON. This situation may occur due to pressing the display Power button, a short circuit in the keypad serial cables, or an incorrect Auto ON/OFF configuration being enabled.

Check the condition of the keypad serial cables and the keypads themselves. Swap keypads and serial cables to identify which component is generating the signal detected as a key press.

Machine left powered on but switches off overnight

Check that OFF mode is not enabled due to a possible misconfiguration of the ON/OFF function or incorrect date and time settings (on machines with display).

Verify whether the installation includes any external power supply scheduling system (smart plugs or programmable timers) that may be incorrectly configured and causing automatic shutdown.

Machine powers on but does not heat

Check that the main power switch is set to position 2 (for three-position switches 0-1-2).

Inspect the thermostat; if it has tripped, reset it. A fault in the temperature control system (pressure switch or SSR) may cause uncontrolled temperature rise, triggering the safety thermostat.

Verify whether the machine is in alarm or lockout state (LED indicators or display).

Measure the resistance impedance to confirm that the heating elements have not failed internally (open circuit).

Check the condition and wiring of the power supply to the heating elements.

Control panel not responding or some buttons not working. What basic checks should be performed?

Verify whether the machine is in an alarm or lockout state (LED indicators or display).

Check if any special function has been activated that may affect display control or machine states (only if documented for the specific model).

If a fault in the push buttons or wiring is suspected, inspect the serial cable connections and swap connections between serial lines and control panels to determine whether the issue lies in the wiring or in the control panel itself.

Display not visible (dark or very dim). Fault or adjustment?

Check the display contrast/brightness setting, if applicable (on many control units the potentiometer may be set to minimum).

After adjusting the contrast, an alarm may become visible on the display, such as “probe interrupted”.

If there is still no visibility after adjustment, treat it as a display or display power supply fault and check whether any related alarm is present in the alarm table.

Machine powers on but shuts off after a few minutes. What are the typical causes?

Check whether the machine enters an alarm state (via control panel and/or display).

Verify if there is a lockout due to low water level or exceeded filling time, according to the alarm table.

If the machine has an LCD display, review the message shown to accurately identify the cause of the shutdown.

Machine powers on but trips the circuit breaker/RCD at startup. What could be the cause?

Cross-check the wiring against the electrical diagram (rated voltage and load distribution).

Check whether the trip occurs when the heating elements are activated or during pump operation, filling, or dispensing.

Disconnect the heating element: if the breaker does not trip, this indicates a possible short circuit in the element.

Disconnect control components one by one, reconnecting and testing operation to identify which component is causing the trip (motor, fill solenoid valves, and then group solenoid valves individually).

If earth leakage or insulation failure is suspected, verify through electrical measurements and locate the leakage point.

Machine does not power on (no lights at all). What should be checked first?

Verify the external power supply (presence of voltage at the outlet or electrical panel) and ensure the machine’s main switch is in the ON position.

If the installation is distributed three-phase, verify that the required phases are present according to the machine configuration (as per the wiring diagram).

If a contactor is present, verify that it switches when powering on; if there are no visible signs, perform an electrical measurement.