Electronics, alarms and unusual behavior
14 questions
The machine does not stop the water flow when a dose button is pressed and it is necessary to press the keypad again to stop it. What could be the cause?
If, after pressing a dose button, the machine does not stop automatically and it is necessary to press the keypad again to stop the water flow, the most common cause is that the control unit is not receiving pulses from the flowmeter.
In this situation, the machine starts the dispensing cycle, but it is unable to measure the water flow, so the dose can no longer operate automatically.
It is advisable to check the flowmeter, its cover, the electrical connections and, if all these components are functioning correctly, the control unit itself.
Display Alarms
The meaning depends on the specific message. The most common alarms are related to boiler filling, temperature, the temperature probe, the flowmeter, the grinding adjustment, filter replacement, maintenance cycles or communication between the display and the control unit. In some cases the machine only reports the problem and in others it remains blocked until it is restarted.
- Excessive filling time
The machine has not managed to cover the boiler level probe within the expected time since filling began. The machine remains inactive and all the buttons on the keypad flash at the same time. It is usually related to lack of flow, restrictions at the water inlet or high work peaks in which the machine does not recover the level in time.
- Boiler temperature alarm / short-circuited temperature probe
It is a single alarm. It appears when the temperature reading exceeds the maximum permitted, either because the boiler has actually overheated or because there is a short circuit in the probe or its wiring and the machine interprets a maximum reading. The machine remains inactive and the long coffee button flashes on all keypads.
- Interrupted temperature probe
The control unit stops detecting the temperature probe for more than 5 seconds. The machine stops because it can no longer regulate the heating correctly. The short coffee button flashes on all keypads.
- Flowmeter alarm
The control unit does not receive pulses from the flowmeter for more than 5 seconds from the start of delivery. It is an individual alarm per group. It does not block the machine, but it prevents the automatic dose cut-off and delivery starts to behave as a continuous delivery, so the user must stop it manually. The LED of the affected selection flashes.
- Grinder adjustment alarm
The machine detects that at the beginning there were pulses from the flowmeter, but afterwards they stop arriving. It interprets that there is a restriction to the passage of water, normally related to grinding that is too fine, excess coffee, excessive tamping or an obstructed filter basket. The LED of the selection flashes.
- Filter replacement
The number of litres programmed to notify of the water filter replacement has been reached. It is a maintenance alarm and disappears after replacing the filter and resetting the filter counter.
- Maintenance alarm / service cycles
The number of services programmed as a maintenance warning has been reached. It is a reminder to carry out the planned intervention and then reset the cycle counter.
- Control unit alarm (only applies to dualboiler machines)
The display has power, but it cannot communicate with the control unit. It is a loss of communication between the display and the control unit. Probably one of the 2 central cables in the control unit or display connectors is making poor contact and prevents data transmission, writing/reading, between both components.
More information in the manual:
Invert LED lighting
This function allows you to modify the visual behaviour of the LEDs on the keypad when they appear inverted compared to the usual mode. On Iberital IB7 and Iberital Intenz, with the machine switched off, you can change to normally off LEDs using on group 1 the combination 1 long coffee + continuous, or return to normally on LEDs using 1 short coffee + continuous. Then, switch the machine off and on again to apply the change.
How to make the delivery time visible on the display
By default, when pressing any button the display shows the text that defines the pressed selection (1 espresso, 2 espressos, 1 Coffee, 2 Coffees and Continuous) on LCD displays in monoboiler machines and the icon corresponding to each type of coffee in dualboiler machines.
Monoboiler machines with LCD display
With the machine switched off, on GR1 keep the Continuous button pressed and switch the machine on without releasing it. The chrono function will appear on the display. The Continuous button on GR1 will remain flashing and will allow you to choose the number of groups: 1 GR, 2 GR, 3 GR or DISABLED. The 2 long coffees button on GR1, which remains steadily lit, is used to change to the setting to keep the chrono visible. In that option, you can leave it as ENABLED so that the chronometers are always visible, or as DISABLED so that they disappear 10 seconds after finishing the delivery. To save the configuration, switch the machine off. When switching it on again, the display will show the delivery time according to the selected configuration.
Additionally, this function can be enabled through the technical menu, by means of the “Chrono” option.
Dualboiler machines with TFT touch display
On Iberital Vista and Expression Pro, this function can be activated from the technical menu, within the “Chrono” option, located in the display submenu and accessible from the first option of the technical menu. When selecting “SHOW”, the display starts to show the chronometer of each group over the icon of the selected dose. Unlike machines with LCD display, in these models the Chrono function does not allow the chronometer to remain visible permanently, but it does allow adjusting how long it will remain on screen once the extraction has finished, by means of the “KEEP” option.
The continuous button remains illuminated
Steady illumination
On Iberital IB7 Handy models, if the continuous button remains individually illuminated with a steady light, it means that the manually filled water tank has reached its maximum level.
What to do
- Stop adding water to the tank.
- Use the machine as normal.
- The continuous button LED will remain illuminated until the water level drops below the maximum level probe, at which point the remaining buttons will also illuminate.
Flashing illumination
When any machine enters dose programming mode, the continuous button remains individually illuminated and flashes.
How to enter this mode
- With the machine switched on, press and hold the continuous button on any group.
- The machine enters dose programming mode.
What it means
If the continuous button is flashing, it may indicate that the machine is in dose programming mode rather than experiencing a fault. Programming mode remains active for 30 seconds after the last interaction with the keypad.
What to do
- Program the required dose.
- Wait 30 seconds without pressing any keypad buttons for the machine to exit programming mode automatically.
- Or press the continuous button on any keypad.
Control unit reset
A control unit reset restores the machine to its factory settings. In addition, on NEW IBERITAL, TANDEM and REFERENT models, the reset also allows the machine to automatically configure the heating option, detecting whether it operates with a pressure switch or a temperature probe.
To perform the reset, the machine must be switched off. Switch it on while holding down the corresponding button combination and continue holding it for a few seconds after start-up. If the reset has been carried out correctly, the buttons will remain illuminated. Then switch the machine off and on again to apply the change.
- The factory reset is performed on group 1 by pressing buttons 1 + 3 + 5 simultaneously. Equivalent to: 1 Short Coffee + 2 Short Coffees + Continuous.
On models equipped with a display, a message such as "Complete Data Reset" or "Factory Settings Reset Completed" will appear.
At what voltage does the flowmeter operate?
The flowmeter accepts a supply voltage of 4.5 to 24 VDC, but the actual operating voltage in the machine is determined by the control unit that governs it. The flowmeter operates in the machines at 5 VDC, because that is the voltage supplied by the control unit.
Where can I find the machine electrical connections?
The connections for the contactor, control unit, display, power button, motor, heating elements or solenoid valves may vary depending on the machine model and version.
For further information, please consult IBDocs, Iberital’s official technical documentation portal, where you will find manuals, electrical diagrams, hydraulic diagrams and model-specific documentation: https://docs.iberital.com/.
Any electrical work must be carried out by qualified personnel, with the machine disconnected from the power supply and in accordance with the relevant safety procedures.
More information in the manual:
The group activates by itself. What should be checked?
Symptom: a full keypad not responding or a button acting intermittently, or spontaneous activations.
Cause:
- Button/microswitch/membrane worn (if always the same button fails).
- Moisture / coffee / detergent inside the keypad (intermittent faults, worse after cleaning).
- Loose connector / damaged wiring / broken track (intermittent contact).
- Control board input damaged (if the issue remains on the same group after swapping keypad/wiring).
- Common ground / interference due to poor electrical contact (random faults, multiple “erratic” buttons, especially with vibration).
Checks / quick test:
- If possible: swap the keypad (or connector) with another →
- If the fault moves: faulty keypad.
- If the fault stays: wiring or control board.
- Check connector condition (oxidation, moisture) and if the issue worsens when moving the cable.
- If it fails after cleaning: high probability of moisture.
One keypad does not work or a button works intermittently. What should be checked?
Symptom: one full keypad is not working or a button is intermittent (sometimes works, sometimes not).
Cause:
- Button/microswitch/membrane worn (if always the same button fails).
- Moisture / coffee / detergent inside the keypad (intermittent faults, worse after cleaning).
- Loose connector / damaged wiring / broken track (serial cable or connector with play, false contact).
- Control board input with cold solder joint or damaged input channel (if swapping keypad does not move the fault).
- Common ground / interference due to poor electrical contact (erratic faults, multiple “random” buttons, especially with vibration).
Checks / quick test:
- If possible: swap the keypad (or connector) with another →
- If the fault moves: faulty keypad.
- If the fault stays: wiring or control board.
- Check connector condition (oxidation, moisture) and if the issue worsens when moving the cable.
- If it only fails after cleaning: high probability of moisture.
The machine shows abnormal behavior (turns off by itself, groups activate simultaneously). What is typically checked?
Abnormal behavior refers to actions that occur without an apparent cause when pressing a group keypad button: the machine turns off (OFF), all groups extract simultaneously, or a group activates by itself.
These anomalies are usually related to short circuits in low-voltage DC wiring or components.
The most affected elements are keypad serial cables, the keypads themselves, flowmeter covers or their connections, and in older machines, possible short circuits on the control board due to stray filaments in terminal blocks connecting ground and level probes.
Dosers change by themselves or do not save programming. What should be checked?
Check whether the machine has entered dose programming mode and whether programming is performed according to the documented procedure (usually by long pressing the continuous button).
If data corruption is suspected, consider performing a factory reset according to manufacturer specifications and reprogram all button doses.
A fault in the flowmeter may prevent pulse generation during programming. As a result, the control board does not store any value and the dose for that button is not saved (the button may appear not to work).
LEDs blink or stay on in an unusual way. What could it indicate?
Do not infer: identify the exact pattern and match it with the alarm table.
Documented example: “Temperature probe disconnected” can also be indicated via the keypad (even without a display), according to the alarm table.
Relation to alarms (if applicable): Example: “Probe disconnected” (temperature) – indicated on keypad and on display if available.
More information in the manual:
An alarm/light appears on the keypad or a message on the display. What steps should be followed before touching anything?
Note the exact pattern: which LED buttons are steady or blinking and whether the display shows any message.
Cross-check with the project alarm summary (alarm table).
Follow the documented action sequence: first resolve configuration or status (for example, perform a reset if applicable and documented), and only then intervene in physical components.
More information in the manual: