Coffee: cup quality and extraction
12 questions
Pre-infusion
Pre-infusion is an initial phase in which the coffee is moistened before applying full pressure. In Iberital machines it is carried out with an ON time and an OFF time:
- during the ON time, the pump and the solenoid valve allow the water to reach the coffee;
- during the OFF time, the pump remains activated, but the group solenoid valve is not, so the water stops circulating through the coffee.
How to enable pre-infusion
The machine must be switched off. Switch it on while keeping the corresponding combination pressed and continue holding it for a few seconds once it has started. If the operation is correct, the buttons remain lit. Then, switch the machine off and on again to apply the change.
- Pre-infusion is enabled on group 1 with button 1.
- Equivalent to: 1 short coffee.
- On models with display, Pre-infusion: Enabled will appear
How to disable pre-infusion
The machine must be switched off. Switch it on while keeping the corresponding combination pressed and continue holding it for a few seconds once it has started. If the operation is correct, the buttons remain lit. Then, switch the machine off and on again to apply the change.
- Pre-infusion is disabled on group 1 with button 2.
- Equivalent to: 1 long coffee.
- On models with display, the following will appear:
- Pre-infusion: Disabled
Special case: pre-infusion in long coffees on Iberital IB7 and Iberital Intenz
On Iberital IB7 and Iberital Intenz, the pre-infusion times cannot be modified. By default, pre-infusion is applied only to short coffees (buttons 1 and 2). If you want it to also work on long coffees (buttons 3 and 4), you must separately activate the pre-infusion function for long coffees. Having this option activated is of no use if general pre-infusion is disabled.
- Pre-infusion in long coffees is enabled / disabled on group 1 with buttons 1 + 2 simultaneously, only on IB7 and INTENZ.
- Equivalent to: 1 short coffee + 1 long coffee.
Dose reprogramming
Dose reprogramming is carried out with the machine switched on. Programming is based on the volume of water, not on time. The control unit counts the pulses from the flowmeter and stores that value for each button.
How to enter dose programming mode
- With the machine switched on, press and hold the Continuous button on any group.
- Keep it pressed until the Continuous button illuminates on all groups.
- At that point, the machine enters dose programming mode.
How to programme a dose
- Once in programming mode, press the dose button you wish to programme.
- The machine will begin dispensing.
- When the desired volume has been reached, press the same button again.
- The machine stores that volume for the selected dose.
Each dose, that is, each button from 1 to 4, is programmed individually.
How programming is replicated between groups
- If programming is carried out from the left-hand keypad, the stored values are replicated to the right-hand keypads.
- The left-hand keypad acts as the master.
- If different doses are required for each group, keypads 2 and 3 must then be programmed separately, if fitted to the machine.
How long programming mode remains active
The machine remains in programming mode for 30 seconds after the last interaction with the keypad, whether from entering programming mode or from completing the programming of a dose.
How programming should be carried out
Dose programming must always be performed with coffee in the portafilter. The total programmed volume includes:
- the volume obtained in the cup,
- the water remaining in the coffee puck,
- and the water discharged during group depressurisation.
Special case for dual-boiler and multiboiler machines
On dual-boiler and multiboiler machines, in addition to manual programming, the dose volume can be modified numerically through the corresponding option in the technical menu.
The recommended procedure is to perform a manual programming first and then fine-tune the numerical value, ensuring that the result remains representative of the actual beverage volume in the cup.
What would be the standard/approximate recipe for my type of coffee?
In an espresso machine, there is no universal recipe that works the same for all coffees. While a standard starting point (dose, time, yield and temperature) can be used, each coffee requires adjustments because extraction behavior and flavor profile vary.
An espresso recipe is defined by four main variables:
- Dose (g in the portafilter)
- Yield (g in cup): defines the ratio (e.g. 1:2)
- Extraction time (s)
- Temperature (°C)
Adjust using this logic:
If the coffee tastes sour/underdeveloped: typically under-extracted → increase temperature, increase yield (ratio) or extend time (finer grind).
If it tastes bitter/harsh: typically over-extracted → reduce temperature, reduce yield (ratio) or shorten time (coarser grind).
How to adjust a grinder?
To understand how to operate your specific grinder, it is recommended to consult the user manual. If unavailable, refer to the manufacturer’s official website and download the corresponding manual.
Symptoms indicating need for adjustment:
- Coffee flows too fast: grind too coarse or insufficient dose
- Coffee flows too slowly or chokes: grind too fine or excessive dose
General adjustment procedure:
- Adjust the grind setting according to the need.
- Use a dose with the new grind setting and weigh the appropriate amount for a single shot (7–10 g). Discard the first grind to ensure consistency with the new setting.
- Perform a test extraction and observe flow rate and puck condition. Repeat adjustments as necessary until optimal extraction is achieved.
- Once the grind setting is correct, fix this variable and adjust dosing by time or volume for single or double shots (12–16 g). Grind setting should not be modified further.
In summary, achieve an optimal grind setting through controlled tests, weighing the coffee and adjusting as needed. Once the grind is set, proceed to fine-tune dosing.
Hot water for infusions appears dirty or white. What should be checked?
Associated symptoms
- Hot water appears cloudy, whitish or with particles.
- Unusual smell or taste in infusions.
- Problem appears after periods of inactivity.
- Partial improvement after purging for a few seconds.
Possible causes
- Limescale or residue buildup in the hot water circuit.
- Lack of boiler water renewal.
- Saturated or incorrect water filter.
- Mineral precipitation due to high temperature.
- Lack of internal boiler maintenance.
Checks / observations
- Purge the hot water circuit for several seconds and observe if it improves.
- Drain the boiler and perform an internal rinse.
- Check the condition and replacement date of the water filter.
- Check the quality of the incoming water.
- If the issue persists after purging, perform internal cleaning.
- In machines with mixing systems, verify correct operation of the mixing valve.
Coffee puck sticks to the shower screen or comes out very wet. What should be checked?
Associated symptoms
- The coffee puck sticks to the shower screen when removing the portafilter.
- The puck is very soft or has excess water on the surface.
- Splashes at the start of extraction.
- Inconsistent coffee between shots.
Possible causes
- Grind too coarse.
- Insufficient coffee dose in the filter.
- Dirty or clogged group shower screen.
- Group exhaust valve not releasing pressure correctly.
- Group gasket deformed or improperly seated.
- Excess residual pressure in the group after extraction.
Checks / observations
- Verify grind size and adjust finer progressively.
- Check correct dose for the filter used.
- Disassemble and clean shower screen and diffuser.
- Ensure that after extraction the group releases pressure correctly to the drain.
- Check the condition of the group gasket and replace if hardened or deformed.
- Confirm that the portafilter locks correctly and is not positioned too low.
Channeling (uneven streams) and splashing. What should be checked?
Associated symptoms:
- Very short pre-infusion time.
- Fast extraction.
- Very soft coffee with little or no crema (observed on a single group).
- Poor coffee extraction efficiency.
- Slow extraction.
- Cold and weak coffee.
Possible causes:
- Worn group jet (gicleur) due to usage.
- Group valve not closing properly.
- Filter basket damaged at the rim.
- Dirty shower screen.
Checks / observations:
- Flow rate without portafilter should be approx. 100 cm³ in 8 to 10 seconds.
- Running the group without portafilter shows thin, uneven streams instead of a uniform central flow.
Coffee tastes burnt or consistently bitter. What should be checked (grind, temperature, cleaning)?
Associated symptoms:
- Slow extraction.
- Burnt and cold coffee.
- Very dark crema, with porous appearance.
- Slow extraction with burnt taste.
Possible causes:
- Grind too fine. Low pump pressure. Filter or group jet partially clogged.
- Pump incorrectly calibrated.
- Reduced pump flow.
Coffee has little crema or appears “watery”. What are the common causes?
Associated symptoms:
- Very short pre-infusion time.
- Fast extraction.
- Very soft coffee with no crema (observed across all groups).
- Very soft coffee with no crema (observed on a single group).
- Cold, weak coffee with normal infusion and extraction time.
Possible causes:
- Coarse grind.
- Old or stale coffee.
- Worn group jet (gicleur).
- Group valve not closing properly.
- Damaged filter basket rim.
- Air bubbles in the thermosyphon circulation.
- Non-return valve not holding (low inlet pressure conditions).
- Possible damage to thermal tubes or faulty boiler pressure gauge (showing higher pressure than actual).
Checks / observations:
- This issue may be linked to other faults; do not adjust grind until other causes are ruled out.
- Idle group flow should be approx. 100 cm³ in 8 to 10 seconds.
- Activate the group 2–3 times to remove possible air pockets.
- Check that the water inlet pipe is warm near the machine.
- Verify pressurestat adjustment is not set too low.
Coffee comes out cold. What quick checks should be performed?
Associated symptoms:
- Poor coffee extraction efficiency.
- Slow extraction.
- Cold and soft coffee.
- Cold, weak coffee with normal infusion and extraction time.
- Cold coffee in the morning at startup.
- Burnt and cold coffee.
- Very dark crema with porous appearance.
Possible causes:
- Dirty shower screen.
- Air bubbles in the thermosyphon circuit.
- Non-return valve not holding (low inlet pressure conditions).
- Possible damage to thermal tubes or faulty boiler pressure gauge (reading higher than actual).
- Too fine grind, low pump pressure or partially clogged filter/group jet.
Checks / observations:
- Running the group without portafilter shows thin, uneven streams instead of a uniform flow.
- Activate the group 2–3 times to remove possible air pockets.
- Check that the water inlet pipe is warm near the machine.
- Verify that pressurestat or temperature probe is not set to low values.
Coffee flows very slowly or “chokes”. What usually causes this?
Associated symptoms:
- Water does not pass evenly through the coffee puck.
- Slow extraction.
- Cold and soft coffee.
- Burnt and cold coffee.
- Very dark crema with porous appearance.
Possible causes:
- Dirty shower screen.
- Grind too fine. Low pump pressure. Filter or group jet partially clogged.
- Pump incorrectly calibrated.
- Reduced pump flow.
Checks / observations:
Running the group without portafilter shows thin, uneven streams instead of a uniform central flow.
Coffee flows too fast (under-extracted). What should be checked first?
Associated symptoms:
- Very short pre-infusion time.
- Fast extraction.
- Very soft coffee with no crema (observed across all groups).
- Very soft coffee with no crema (observed on a single group).
- Fast extraction with weak coffee.
- Poor coffee extraction efficiency.
- Fast extraction with hot but weak coffee.
Possible causes:
- Coarse grind.
- Old or stale coffee.
- Group valve not closing properly.
- Damaged filter basket rim.
- Pump incorrectly calibrated.
- Blocked bypass valve.
- Filter baskets with oversized holes.
Checks / observations:
- This issue may be related to other causes; do not adjust grind until they are ruled out.
- Idle group flow should be approx. 100 cm³ in 8 to 10 seconds.
- Coffee grounds present in the cup.